Lightning strike counter calibrator use notes seven points

Lightning counter counter calibrator use precautions Seven points 1. Charge before use, in order to ensure the charging effect and extend the battery life, you need to use a dedicated charger. Empty battery to full 3-4 hours, the charger red light Light indicates that charging is in progress; green light indicates charging is completed. Plug the grounding plug at the end before use, and the ground wire is clamped to the ground.

2. According to the height of the counter installation, properly pull out the telescopic discharge rod.

3. Press the red button to turn on the high voltage for about 1 second, the indicator light is on (slight flash), you can click the connection between the counter and the arrester to test.

4. After each click, the end of the discharge rod should leave the counter. If you need to repeat the test, you don't need to release the button. After about 1-2 seconds, the indicator will flash again, you can click the test again.

5. Continuous testing will cause the tester to heat up, please pay attention to the appropriate interval time.

6. If the button is still not flashing after pressing the button for more than 3 seconds, it means that the battery needs to be charged.

7. Do not disassemble the calibrator. If the battery capacity drops significantly or the charging efficiency is too low, you need to change it. Please purchase a special battery pack from our company.

Note: When the indicator light is on (slight flash), no part of the body can touch the electrode part, otherwise there is a danger of electric shock.
Lightning counter counter calibrator use method . 1. Charge before use, in order to ensure the charging effect and extend the battery life, you need to use a special charger. Empty battery to full 3-4 hours, the red light on the charger indicates Charging is in progress; the green light indicates that the charging is completed. Plug the grounding plug at the end before use, and the ground wire is clamped to the ground.

2. According to the height of the counter installation, properly pull out the telescopic discharge rod.

3. Press the red button to turn on the high voltage for about 1 second, the indicator light is on (slight flash), you can click the connection between the counter and the arrester to test.

4. After each click, the end of the discharge rod should leave the counter. If you need to repeat the test, you don't need to release the button. After about 1-2 seconds, the indicator will flash again, you can click the test again.

5. Continuous testing will cause the tester to heat up, please pay attention to the appropriate interval time.

6. If the button is still not flashing after pressing the button for more than 3 seconds, it means that the battery needs to be charged.

7. Do not disassemble the calibrator. If the battery capacity drops significantly or the charging efficiency is too low, you need to change it. Please purchase a special battery pack from our company.

Note: When the indicator light is on (slight flash), no part of the body can touch the electrode part, otherwise there is a danger of electric shock.