Electronic strip length measuring device repair and maintenance

First, product use and scope of application

This instrument is used to shake the slivers and rovings of cotton, wool, silk, silk, etc. to a specified length.

Second, the main specifications and technical features

1 Measuring wheel circumference: 1000±1mm

2 measuring wheel width: 250mm

3 Number of feeding heads: Double or single head 4 Roller diameter: 62mm

5 Roller weight: 4300±50g

6 digital display: 0 ~ 99.9m

7 minimum resolution: 0.1m

8 Operation: Hand 9 Dimensions: 610×485×550mm

10 weight: about 40Kg

Third, the instrument structure

The left and right brackets of the instrument are fixed with upper and lower supporting members and nuts, and are fixed on the bottom plate with the foot screws. The length of the measuring wheel installed between the brackets is 1000mm. Its axis is mounted on the left and right brackets, and a swing handle is mounted on one end to make it rotate. The right side of the length measuring wheel is equipped with a grating wheel, and the grating wheel is divided into ten equal parts, each of which is equally divided into 36 degrees, and is processed into a digital display through a photoelectric coupling tube and a shaping circuit. The display value is 0.1m, and the length measuring wheel rotates. In a circle, the digital display has a display value of 1.0m for counting. The front of the measuring wheel is mounted on the bottom plate so that the cotton sample can be placed. The left and right brackets have two straight slots at the upper end. One is not working, and the pressure roller makes contact with the surface of different measuring wheels. When the other is working in a straight slot, it can be pressed directly to the measuring length by means of a press roller. On the turn. The creel for the installation of the cotton sample is a bracket, and the height can be arbitrarily expanded and contracted. At the same time, it is used for wool and cotton spinning plants, and only the height of the bracket is adjusted, and the operation is extremely convenient.

Fourth, the installation and adjustment of the instrument

This instrument is packed in a box and shipped from the factory. The structure is relatively simple, and it can be used after it is placed smoothly after unpacking.

Fifth, the instrument repair and maintenance

5.1 Maintenance cycle The instrument maintenance cycle is once a year. If it is deactivated for a long time, the surface of the measuring wheel should be coated with thin oil or heavy oil to prevent rust on the surface. During work, pay attention to the yarn coming into the groove of the measuring wheel (5) and the right bracket (10), and touch the grating wheel (11) to prevent the photoelectric coupling tube from being damaged.

5.2 Lubrication of the Instrument Lubrication cycle of the instrument is once per shift, and 2 to 3 drops of oil should be injected into the oil cups of the left and right brackets. A small amount of butter must be added to both ends of the yarn fulcrum to allow the instrument to operate normally. .

5.3 Cleaning of the instrument The instrument should be used in the test room under possible conditions. The cleaning work should be done once after each shift. If used in the production workshop, besides the class should be done cleaning work, we must pay special attention to whether the bearings, oil cups in the eyes are blocked by flying flowers, and ensure that the eyes of the oil cup open.

Http://Product_8235384.html

  • Suitable for industrial scenarios.
  • Help to resume work and production.
  • Protect the company's safe and healthy development foundation.
  • KN95 details display

Personal Protective Mask

Kn95 Cup Type Mask,Non-Sterile Face Mask ,Face Mask Disposable Earloop,Medical Mask Earloop

Dongguan zhenqingkuai Technology Co., Ltd , https://www.ppaepp.com

Posted on