Bearing lubricating oil; high load-bearing function; good oxidation stability; high rust-preventing function of high-quality mineral oil or composition oil. When selecting lubricating oil; the first is based on working speed; the oil with the right viscosity is selected. The viscosity is too low; it can not form an oil film; it is the cause of abnormal wear and burning. The opposite viscosity is too high; the heat is formed by viscous resistance; for example, the rotational speed and load of the bearing with large power loss also affect the composition of the oil film. The faster the rotation speed; the lower the viscosity of the oil is used. The larger the load, the larger the bearing; the higher the viscosity of the lubricating oil used.
Under normal operating conditions; the general specification of the viscosity of the lubricating oil corresponding to the oil temperature around the bearing in operation.

Recommend to friends comments close window

Bearing related knowledge
Power plant high-voltage motor bearing "protection technology common sense" inventory double row cylindrical roller bearing classification rolling bearing residual magnetic skill conditions (2)
Talking about the electric corrosion of bearings
NSK imported bearing protection strategy


This article links to http://
Please indicate the bearing network http://

Previous:The result of SKF bearing oscillations: The occurrence of bearing oscillation

Chlorine dioxide when used as an effective disinfectant forms undesirable disinfection by-products, i.e. chlorite and chlorate ions. The aim of this research was to study the removal of these ions byferrous ions in the presence or absence of oxygen. The efficiency of Fe+2 for ClO2- and ClO3- removal was followed by a determination of their initial and final concentrations, pH and delta Fe+2 consumed/delta ClO2- removed ratios. The optimal weight ratio of delta Fe+2 consumed/delta ClO2- removed for complete ClO2 removal was found to be close to the theoretical calculated value of 3.31. It was proved that ferrous salts can reduce chlorite ions to harmless Cl- ions. This method can be recommended as a part of ClO2 disinfection to ensure safe drinking water, with no harm to waterconsumers and to the environment.

*Related Products:clo2 disinfectant.

Potable Water Disinfection

Clo2 Generator Tap Water Disinfection, Clo2 Generator Well Water Disinfection, Clo2 Generator Ground Water Disinfection, Clo2 Generator Drinking Water Disinfection

Nanjing Ligong Shuifu Environmental Protection Technology Co.,Ltd. , http://www.watermanclo2.com

Posted on