Lightning protection precautions for building intercom

At present, the rated voltage of the majority of building intercom door power supply on the market is 220V, the AC peak or composite voltage is 190-250V, and the test voltage of the anti-electric strength should be 1.5kV. To meet this requirement, it can only meet the requirements of sudden changes in the circuit system, but it cannot resist the lightning overvoltage and excessive current. At present, most residential building intercom doors do not have any lightning protection measures. Therefore, building intercom doors should have lightning protection and grounding devices.

There were times when some building intercom doors were damaged by lightning. This caused great inconvenience to the user and also caused large economic losses. Through the investigation and analysis of the causes of these lightning strikes, the main components of the crash are the power box, circuit board, and the talking machine. The main methods of lightning strikes are:

(1) Directly hit mine. Direct lightning strikes the lightning directly on the object. The thundercloud near the ground induces an opposite charge on the protrusion. When the electric field strength between the thundercloud and the ground protrusion reaches the air breakdown strength, it will strike. Wear discharge, this type of thundercloud directly puncture discharge on the ground protrusion is called direct lightning. High buildings and their sides are subject to direct lightning strikes, and direct lightning strikes on the side of a building can be called side impact mines.

(2) Induction of thunder. Lightning strikes a conductor, such as a metal object next to the device, and indirectly strikes the object. Lightning induction is divided into electrostatic induction and electromagnetic induction. The formation of electrostatic induction is due to the induction of a large number of opposite charges on the top of ground projections when the cloud approaches the ground. When the thundercloud and other thunderclouds or other objects are discharged, the accumulated charge on the top of the protrusion suddenly loses its bondage, showing a high voltage and rapidly propagating in the form of lightning waves. The formation of electromagnetic induction is due to direct lightning currents that produce a rapidly changing strong magnetic field in the surrounding space, which induces high voltages in nearby metals. Induction mines are not as violent as thunder but they are much more likely to occur than direct thunder. Because direct lightning strikes only when lightning strikes the ground, it will cause disasters to the ground. Induction lightning, however, strikes lightning regardless of the lightning strikes on the ground, or lightning strikes between thunderclouds may occur and cause disasters. A lightning stroke can occur in a relatively large range and multiple small parts at the same time, and this induced high voltage can be transmitted far through the signal wires, power lines, telephone lines and other metal wires, resulting in lightning The scope has expanded. The following measures should be taken to prevent the above major lightning strikes:

1. The installation position of the power box should be properly selected. (1) Avoid installing on the side wall of the house, especially on the side wall of the projected house, so as to prevent direct lightning strikes. (2) Avoid installation on the side of a pipe where there is a metal pipe, a gas pipe, etc. Especially, the same side wall that is less than 5 meters from the metal pipe and the air pipe can not be installed.

2. Both the power box and the circuit board should be grounded. The grounding wire should be solid and reliable, and the grounding resistance should be ≤ 0.1Ω.

3, wiring should be correct and reasonable. Power lines and signal lines should be placed indoors to avoid outdoor wiring as much as possible, avoiding the same direction and cross wiring as metal pipes, air pipes, etc., and it is impossible to avoid wiring in the same direction as metal pipes, gas pipes, etc. The distance between the two should be ≥ 5 meters. . The wiring should be laid in a straight line to minimize bending wiring.

4. The power source of the power box should be connected to the power socket. When weather is prevented or weather changes may cause lightning, it is convenient to cut off the power in time to prevent lightning strikes.

15 inch length with 3 inch width helix auger Earth Anchor. Package quantity: 1pc
Powder coated red color. Weld eye ring for installation and tie off. Firmly welded helix.
Easy installation by hand or machine
Screw into the ground to guy down tents, canopies, storage buildings, fencing, playground equipment, trees, as well as more other guying uses.

Earth Anchor

Earth Anchor,Earth Screw Anchor,Paint Earth Anchor,Earth Screw

Hebei Honde Plastic & Metal Co., Ltd. , https://www.foundation-system.com

Posted on