Causes of Common Faults and Treatment Methods of Sanitary Double Helical Pumps

Health-class double helical pump in the use of the process, there may be some failures, we must learn to handle their own in order to improve work efficiency, Xiao Bian deliberately inventory health double helical pump causes and treatment of common failures . Sanitary double helical pump Sanitary double helical pump common causes and troubleshooting methods Fault performance Fault causes Troubleshooting No discharge or discharge too little 1, the valve did not open or into, the discharge line is blocked. Open the valve and clean up the blocked line. 2, the pipeline process is complicated, resistance is too large. Simplify and shorten the pipeline. 3, equipment reversal. Adjust the motor power wiring. 4, the viscosity of the material is too large. Pump or dilute the material. 1, open the valve, clean up the blocked pipe. 2, simplify and shorten the pipeline. 3, adjust the motor power wiring. 4, the use of pump delivery or dilution of materials. Equipment vibration, issued a metal friction sound 1, by the metal or hard to break the impact of impurities, resulting in spindle eccentricity. Remove impurities, replace the spindle, repair or adjust the gear to ensure that the normal position of double-helix head friction. 2, by the impact of metal or difficult to break the impurities caused by minor spiral head deformation. Replace the spindle, repair or adjust the gear to ensure the normal position of the double helix head frictionless. 1, remove impurities, replace the spindle, repair or adjust the gear to ensure that the normal position of double helix head frictionless. 2, replace the spindle, repair or adjust the gear to ensure that the normal position of the double helix head frictionless. Equipment suddenly does not work, the shaft does not move 1, received the metal or difficult to break the impact of impurities, resulting in eccentric or fixed spindle, rotor deformation bite death. Remove impurities, replace the spindle, repair or adjust the gear to ensure that the normal position of double-helix head friction. 2, the material viscosity is too high or excessive pump flow overload trip or motor burn. Adjust the viscosity of the material, select the flow matching feed pump. 1, remove impurities, replace the spindle, repair or adjust the gear to ensure that the normal position of double helix head frictionless. 2, adjust the viscosity of the material, select the flow matching feed pump. Leakage 1, oil seal damage Replace the oil seal 2, static seal damage. Replace the static seal 3, sealed face uneven force. Adjust the sealing face of the force 4, the mechanical seal leaks. Replace the mechanical seal ring or moving ring. 1, replace the oil seal 2, replace the static seal 3, adjust the sealing face force 4, replace the mechanical seal ring or moving, static ring. Further Reading: pump valve pipe fittings Exhibition 2016 Exhibition of Information Industry, Internet (Xiamen) Technology Co., Ltd. Author: Asian pumps Network Editor: Yao Xiaoxia (QQ / micro letter:) http://beng.liuti.cn/ (Hotline :)

First, the product description:
    Water-based Curing Agent is a polymer water-based emulsion, spray the surface of the newly poured cement concrete to form a protective film, plug the concrete pores, delay water evaporation, the concrete surface to form a continuous transparent film, sufficient Hydration to achieve conservation results.
Second, the performance characteristics:
1, construction is convenient
2, is an aqueous product, will not cause damage to the human body, the environment and pollution.
3, good conservation effect, does not contain any damage to the quality of cement concrete ingredients.
4, the nature of the emulsion used in this product is stable, non-toxic.
Third, the scope of application:
New cast concrete surface such as: roads, airports, large cement concrete projects, concrete components, wear-resistant floor and so on.
Fourth, the construction process:
1, the material should be fully mixed before use.
2, the final surface of the concrete surface after calendering can spray evenly on its surface Curing Agent.
3, construction time is about 1-2 hours after calendering (depending on the ambient temperature and humidity at the time) The basic requirement is that the surface has no free water. If there is no spraying equipment, can also be used soft brush or roller construction, construction should be cautious operation, so as not to damage the concrete surface.

Water-Based Curing Agent

Water-Based Curing Agent,Water-Based Reactive Curing Agent,Water-Based Curing Agent Ks-3C02,Water-Based Curing Agent Ks-3C01

Jiangmen Kasole Building Materials Co., LTD. , https://www.kasole-paint.com

Posted on