Tips: Emergency lighting and evacuation indicator system

The emergency lighting and evacuation indicator system is a system that provides lighting and evacuation instructions for people who need to work normally in the event of evacuation and fire, and consists of various types of fire emergency lighting and related devices. Fire emergency lighting refers to all kinds of lamps and lanterns that provide lighting and signs for evacuation and fire fighting operations, including fire emergency lighting, fire emergency signs, and fire emergency lighting signs. The evacuation indicator sign refers to a sign that is used to indicate the role of a person in a safe evacuation during a fire.

(1) Installation requirements and function indicators of emergency lighting fixtures 1. Kitchen: The area shall be within 100m2, and 3 (4) fire extinguishers shall be provided, and 1 fire extinguisher shall be added for every 50m2 added.

2, material library: area within 50m2, equipped with not less than one fire extinguisher, each increased by 50m2 increased by more than one fire extinguisher (such as the storage of more combustible materials in the warehouse, to be increased accordingly).

3. Construction office area and cement warehouse: The area shall be within 100m2. There shall be no less than one fire extinguisher, and no less than one fire extinguisher shall be added for each 50m2.

4. Combustible goods yard: The area is within 50m2, and no less than 2 (4) fire extinguishers are provided.

5, motor room: the configuration of fire extinguishers is not less than one. 6, electrical room, power distribution room: the configuration of fire extinguishers is not less than one.

7, vertical transport equipment (including construction elevators, tower cranes) cab: the configuration of fire extinguishers is not less than one.

8. Oil storage area: Within 50m2, no less than 2 (4) fire extinguishers and no less than 1 fire extinguisher per 50m2.

9. Temporary flammable and explosive materials warehouse: The area is within 50m2, and no less than 2 (4) fire extinguishers are provided.

10. Wooden workshop: Within 50m2, no less than 2 (4) fire extinguishers and 1 fire extinguisher per 50m2.

11. Duty room: 2 fire extinguishers and 1 fire hose with a diameter of 65mm and a length of 20m.

12. Collective dormitory: 1 fire extinguisher per 25m2. If the floor area exceeds 1000m2, a 2m fire-fighting pool should be established for each 500m2.

13. Temporary hot work places: No less than 1 fire extinguisher and other fire-fighting aids are provided.

14. Buildings under construction: The area of ​​the construction layer shall be within 500m2, and no less than 2 fire extinguishers shall be provided. One fire extinguisher shall be added for each additional 500m2. The non-construction layer shall be equipped with fire extinguishing equipment as appropriate.

Sensor Led Down Light

Specifications

Recessed LED Downlight with built-in Microwave Motion Sensor

Model AM-6.0GY
Luminous flux 800~900lm
Luminous Efficacy >80lm/W
Colour Rendering index 80
Beam Angle 140°
Light Decay <30% over 10,000 hours
Rated Lifespan >30,000 hours
Power consumption 10 watts
Input voltage / Frequency 80-260vac 50-60HZ
Reflector / Diffuser Frosted diffuser
Operating Environment -20°c~+50°c
Dimensions Φ193*77mm
Hole Cut Size Φ160~Φ180mm
LED Source 56pcs SMD2835
Working mode ON/OFF or Full/Dim
Sensor Range 180*360 degree
Sensor Distance 6-8m Radius
Delay Time 18-25s
led

Sensor Led Down Light,Recessed Led Down Light,Led Ceiling Down Light,Smart Down Light

JIANGMEN MOSCOT OPTOELECTRONIC TECHNOLOGY CO.,LTD. , https://www.zjsensorsled.com