Submersible pump 8 factors cause no water or insufficient flow

The submersible pump has 8 factors that cause no water or insufficient flow. Because many submersible pumps are made of cast iron or plastic, it is difficult to meet the needs of customers if they only use submersible pumps made of these materials, such as many corrosive The medium cannot be discharged, such as sulfuric acid, hydrochloric acid, nitric acid, etc.; this is one of its characteristics.
The submersible pump has 8 factors that cause no water or insufficient flow. Because many submersible pumps are made of cast iron or plastic, it is difficult to meet the needs of customers if they only use submersible pumps made of these materials, such as many corrosive The medium cannot be discharged, such as sulfuric acid, hydrochloric acid, nitric acid, etc.; this is one of its characteristics. Another feature is that it is resistant to high temperatures in addition to rust. Therefore, many manufacturers have produced high-temperature resistant stainless steel "target=_blank> stainless steel submersible pumps. Although it is stainless steel "target=_blank> stainless steel, but there are many auxiliary materials that can not withstand much high temperature, generally within 120 ° is no problem, such as Some chemical plants need to use a centrifugal pump if they need to withstand more than 200 degrees of high temperature.


1. Submersible pumps often have insufficient flow or no water during operation. The main reasons are:
(1) The installation height of the pump is too high, so that the impeller immersion depth is not enough, resulting in a decrease in the water output of the pump;
(2) the opposite direction of the pump;
(3) The outlet valve cannot be opened;
(4) The water outlet pipe is not smooth or the impeller is blocked;
(5) The wear ring at the lower end of the pump is seriously worn or blocked by debris;
(6) The liquid density of the pumping liquid is too large or the viscosity is too high;
(7) The impeller is detached or damaged;
(8) When multiple pumps share the output of the pipeline, the one-way valve is not installed or the one-way valve is not tightly sealed.

2. Exclusion measures
(1) Control the allowable deviation of the pump installation elevation, and do not expand at will;
(2) Before the pump is tested, the motor is idling and the steering is checked to make it consistent with the pump. If the above situation occurs during use, check whether the power phase sequence changes.
(3) Check the valve and maintain the valve frequently;
(4) Clean up the blockage of the pipeline and the impeller, and often salvage the debris in the reservoir:
(5) Clean up debris or replace the wear ring;
(6) Finding the cause of water quality changes and treating them;
(7) Reinforce or replace the impeller;
(8) Add or replace the one-way valve after checking the cause.