Analysis: Eight major misunderstandings in the purchase of solid wood composite flooring

Today, in the process of purchasing solid wood composite flooring, consumers have blindly pursued precious wood, color and other phenomena. In this regard, it is summarized as 8 misunderstandings.

Blindly pursuing precious laminate flooring

At present, there are dozens of solid wood composite floorings on the market. The prices, performances and materials of different tree species are different. The majority of citizens should purchase according to their own economic strength, decorative style, personal preference, etc. The better the performance of the material.

Blindly pursue panel thickness

The thickness of the panel of the three-layer solid wood composite floor is preferably 2 to 4 mm, and the thickness of the panel of the multi-layer solid wood composite floor is preferably 0.6 to 2.0 mm, and the thickness of the panel should not be excessively pursued.

Blindly pursuing cheap prices

When buying solid wood composite flooring, you must not buy the "three no" products only as cheap. Priority is given to branded products that are certified by the state or industry and are reputable.

Ignore environmental technology requirements

It is reported that compared with the ordinary floor, the golden eyes of the Bondi golden eye floor constitute a breathing passage, which is more complete and more thorough in order to achieve more environmentally friendly and healthier requirements.

Ignore mute requirements

“The floor mute requirement is easy to ignore at the purchase site. In this case, consumers need to conduct more field visits to the sample room and ask for mute problems and requirements.” Mr. Chen said.

Ignore the stability requirements

The author was informed that Bondi Golden Eye Floor pioneered the honeycomb stress system technology, which greatly enhanced the stability of the floor and greatly extended the life of the floor.

Heavy color

The panel of the parquet is natural wood. Because of the location of the plant, the sun, the temperature and humidity, the wood color is definitely different. This is a natural phenomenon.

Light maintenance

Daily cleaning of the floor plays an important role in extending the life of the floor. Wood flooring is most resistant to the corrosion of chemicals, the contact of hot objects, and the pressure of heavy furniture. If the floor is stained, such as vinegar, salt, oil, etc., use some special cleaning products, do not use gasoline to clean.

[WeChat public number " Jiuzheng floor network ", pay attention to courtesy, scan code to send millions of business opportunities! Jiuzheng floor network exchange group]

The Installation of Mounting Unit
1. Make the concrete base according to solution drawing, locate embedded bolts and set out strings by Laser Level to ensure the centers of embedded bolts in the same elevation as accurate as possible on vertical, horizontal direction and at end face.
2. Locate the Anchor Plate on the concrete base and adjust the position according to solution drawing(remove M14 washer,M14 spring washer,and M14 nut if they are connected to embedded bolts now),and then fasten M14 washer, M14 spring washer, and M14 nut with the tightening torque of 60N.m.
3.Take out the Hexagon Bolt Kit with Post B Corrugated Gasket M12x95 and remove its nut, spring washer, one washer, and corrugated gasket. Insert the Post A, B, C in to Anchor Plate according to the Hexagon Bolt Kit with Corrugated Gasket M12x95 drawing and then fix them by two sets of Hexagon Bolt Kit with Corrugated Gasket M12*95. Post C Post A
4.Remove the bolt kits M12*90 from all the Posts and Pre-Assembled Supports and unfold the embedded Supports, fasten them on the Posts by bolt kits M12*90 according to the drawing. 

Installation of Rails
1.Please check the length of Beam before place it onto the Pre-Assembled Supports, otherwise extend it with Splice forBeam first. There are 4 self-tapping screws in each side and total 8 self- tapping screws in both sides. We strongly recommend NOT extend the Beams on Preassembled Supports.
2.Before locate the Beams, mark the position of the Beam son the surface of Pre-Assembled Supports with maker pens according to solution drawing for easier installation. Place the Beams on the 55*80 Tube of Pre-Assembled Supports and fix it with C Clamp Kits. Install all the Beams in the same step. The tightening torque will be 20N.m. C Clamp Kit Side Beam(Please arrange 3-4 persons to install when the array is long.)

Installation of Solar Panels
1.Place the panels above the Beam 85, fixing it with Wide End Clamp Kit in the side and Inter Clamp Kit in the middle. Install all the panels in the same steps until complete installation of al panels. Fasten all the bolts with tightening torque of 10N.m.
2.Complete installation, and please inspect and make sure all the bolts are fastened.

Solar Mounting System For Green House

Solar Panel Mounting Frames,Solar Panel Mounting Systems,Greenhouse Solar Mounting System,PV Mounting Systems

Hebei Honde Plastic & Metal Co., Ltd. , https://www.foundation-system.com

Posted on